Feature

●Adjustment roller: the adjustment roller is used for adjustment, which is convenient for the user to replace the hose to avoid pinching and destroying the hose due to lack of experience of the user
●Step motor: the motor of the pump is a stepper motor with high control accuracy, low power consumption and stable performance
●Quick to disassemble: the pump lid can be screwed by hand to quickly disassemble it and simplify hose change
●Silent: the roller bearing adopts a quiet and durable wheel frame


Description

pump head

Pump Cover Color Black
Engine power Approx. w30
Shell material Nylon
Roll material POM plastic (polyacetal)
Roller Type Ball bearings
Pump pipe Inner diameter x outer diameter 6.4mm x 9.6mm, wall thickness: 1.6 mm, maximum diameter: 9.6 mm
Pump head flow per turn 1.5 ml, the recommended speed is less than 400 rpm
Number of rolls 3
Note: 42 stepper drive and control circuit and power supply are required to be used

motor

Winding DC resistance (25°C) 2.5Ω ± 10%
Winding inductance 5 mH ± 20%
Actuating torque 18 mN.m REF
Holding Torque ≥440 mN.m (two-phase rated current I = 1.3A)
Max. Start frequency without load ≥1500 pps
Max. Idle frequency ≥8000 pps
Temperature rise <80 K
Step angle accuracy 1.8 degrees ± 5%
Moment of inertia 57 g.cm2
Drive mode Constant current chopper drive
Excitation mode 2-phase excitation (2-phase four-stroke operation), can rotate forward and backward
Steering Turn on in order AB-BC CD-DA, see C.W from shaft extension end
Working voltage: 6 V ~ 30 V (depending on the drive voltage used)
Rated current (single phase) 1.3 A DC
Rated voltage 3.25 V
Working conditions Working environment temperature: -20~50℃; relative humidity: 90% MAX (test conditions: normal atmospheric test conditions)
Insulation class Insulation class B
Insulation resistance The cold insulation resistance between the iron core of the stator and the motor terminals should be greater than 100MΩ (measured with a DC500V megohmmeter).
Dielectric strength The stator core of the motor and the terminals should be able to withstand AC600V/1S without failure, and the leakage current should be less than 1mA.
Installation position Shaft horizontal or vertical installation
Wiring Method Red A+, Blue A-, Green B+, Black B-
Package list 1 x pump, 1 x hex key

Installation dimensions drawing

Installation dimensions drawingInstallation dimensions drawing