Protection features:
High temperature protection: When the temperature is higher than 60 degrees, the cooling fan starts to work. The inverter stops operation when the temperature is above 80 degrees. Low voltage alarm: If the input voltage falls below 10.5V, the inverter indicates that the power is low. Low voltage protection: If the input voltage is below 10V, the inverter will turn off after 5 seconds. High voltage alarm: The inverter stops operation when the input voltage is above 15 V. Short circuit protection: The inverter stops operation when the load is short-circuited. Overload protection: With a load power of more than 1000W and less than 1050W, the inverter emits an alarm but does not turn off. With a load power of more than 1050W, the inverter shuts off after 5 seconds.