Technical data:
Model: AC-15A.
Material: aluminium.
Nozzle size: 1 inch (25 mm).
Flow rate: 4.5 m³/h
Pressure: 0.25 MPASuitable liquid: diesel, kerosene, petrol
Weight: approx. 1415 g.
Instructions:
1. Two buttons (calibrate) and (display).
2. When you change the unit, press and hold the button (CALIBRATE) for 5 seconds. The numbers shown flash from left to right. Press (display) to reach the last position. The unit flashes from top to bottom and then press (CALIBRATE) to select the unit.
3. Standby state: the standby state is a low power state. If there is a measurement pulse input, the filling quantities are displayed in real time.
4. The measuring range is 9999.9. If this range is exceeded, it will automatically reset to zero.
5. Reset the capacity in real time: press the button (DISPLAY) to reset the real-time quantity to zero. Reset the cumulative quantity: take out the battery and hold (DISPLAY) when you insert the battery back to reset the cumulative amount.
6. The standard unit for real-time measurements is litres (LRT).
7. Press in standby mode or when the capacity is displayed in real time (CALIBRATE) to display the cumulative capacity.
8. Release the button (CALIBRATE) or when a measurement pulse is entered, the display returns to the real-time filling quantity.
Package includes:
1 x oil gun nozzle.
1 x plug.