Voltmeter self-calibration instructions:
1. When the built-in voltmeter shows the output voltage, press and hold the right button for 2 seconds to enter output voltage control mode, and the display of the voltmeter and the output voltage indicator flash synchronously. When the built-in voltmeter shows the input voltage, press and hold the right button for 2 seconds to enter input voltage control mode, and the display of the voltmeter and indicator light flash synchronously.
2. Press the right button to increase the voltage value and the left button to reduce the voltage value. Due to the voltage unit of less than 0.1V, you need to press the button 1 time ~ 5 times to see how the voltage value changes by 0.1V.
3. After you have set the voltage, press and hold the right button for 2 seconds and then release it to exit the voltage calibration mode. All configured parameters are automatically saved in the event of a power failure.