Feature

●Two types: This sensitive temperature controller for digital display can set Celsius or Fahrenheit mode
●Useful: The display and control temperature can be set to 0.1. Installation is convenient and wiring easy
●High temperature protection: Wide temperature measuring range from -50 to 110 and support high temperature protection
●Easy to install: Can be installed directly or quickly into industrial panel panels
●Occasions: Widely used in hatching, equipment case, air conditioning, temperature control protection and other areas


Description

Smart thermostat with DC12V digital displaySmart thermostat with DC12V digital display

Description:

Input voltage: DC 12 V

Temperature measurement range: -50°C ~ 110°C

Resolution ratio: -9.9 ℃ -99.9 --0.1 other temperature ranges - 1

Measuring accuracy: 0.1 °C

Control accuracy: 0.1 °C

Accuracy of return difference: 0.1 °C

Refresh rate: 0.5 S

High temperature protection: 0 - 110 °C

Measuring input: NTC waterproof sensor (10K 0.5%)

Output: 20 A relay

Environmental requirements:

Temperature requirements: -10 °C ~ 60 °C

Moisture requirements: 20% - 85%

Power consumption of the machine: static current 35 MA, inrush current ≤ 65 mA

Weight: 33 g / 1.2 oz (approx.)

Smart thermostat with DC12V digital displaySmart thermostat with DC12V digital display

How to use:

After connecting to the power supply and load (see wiring diagram), you can power the regulator, the red colour manifest for temperature measurement, the following colour blue (or red) as needed to adjust the temperature

If the actual temperature is displayed and please press the set button, the following digital setting text flashes and temperature, after completing the setting, wait for 3 that automatically returns. At this point, the controller automatically disconnects the relay according to the preset temperature, this sensor can meet all kinds of high-performance loads, make sure the line is correct

The status description of the light and digital tube:

Display: This means that the relay is not connected and the normal light indicates that the relay is closed.

Digital tube: LLL sign is the open circuit of the sensor and HHH sign means outside the measuring range, the controller separates the relay violently, the sign means high temperature protection

Temperature controllerTemperature controller

Temperature controllerTemperature controller

Temperature controllerTemperature controller

Temperature controllerTemperature controller

Smart thermostat with DC12V digital displaySmart thermostat with DC12V digital display

Tips:

Connect power and load to power the controller. At this time, the top red display shows the measured temperature and the lower blue (or red) display the desired set temperature. Press STC (+) C / F (+) to set the desired setting temperature, wait 3 seconds after completion of the setting and automatically confirm the return. At this point, the controller automatically turns the relay on and off depending on the setting. The thermostat output consists of 10 relays, which meet the requirements of loads with high performance. The connection is correct.

Customer Reviews
Price
Code Explain Adjustment range: Factory Settings
P0 Heating / cooling H/C C
P1 Return Difference 0.1-30 2.0
P2 Set maximum limit set + 110 110
P3 Set the limits to the minimum - 50 - 50
P4 Temperature correction - 15-15 0
P5 Delayed start 0-10 0
P6 High temperature alarm -50~110 Off
P7 CS/FH CS
P8 Reset to factory settings ON-OFF Off

The description of the parameters function:

Please press the SET button for five seconds and you can then enter the main menu of the settings by pressing STC (+) and C / F (-) to switch to P0-P8.

By setting the parameters P0-P8, if you need to set P0, please first press STC (+) and C / F (-) and the P0 figure flashes, then please press STC (+) and C / F (-) to set up, then press STC (+) and C / F (-) to confirm the parameters of each code such as P0. according to the needs of your can be adjusted.

The C/F button is a button for switching between Fahrenheit or Celsius

Press the button C / F once, and it will display F (Fahrenheit mode), and then press the button C / F once, C (Celsius mode), the default mode is C (Celsius mode), if there is a large temperature error when you use it, it may be the F mode.

An example of the setting:

If you need to control the cooling system

1: Please set to C mode in code P0:

2: When the actual temperature is displayed, you should press the SET button, and the following number of the setting text flashes, then press C/F (+) and SET (-) to set the stop cooling temperature, please wait 3 seconds after setting, the return will be confirmed automatically.

3. Return difference setting: First, please press the SET button all the time for five seconds, and the setting main menu will be opened. Then press STC (+) and C / F (-) to switch in P1, when you switch in P1, please press STC (+) and C / f (-) once, the P0figure flashes, then please press STC (+) and C / f (-) to set the difference value (return difference means you should add some degrees to start, for example. if the device stops If the stop setting temperature is 25 degrees, you need to set the cooling temperature to 28 degrees. The value in the code P1 should be set to 3 degrees, i.e. the return difference value is 3 degrees), finally press STC(+) C/F (-) to confirm simultaneously.

4: The above steps are set up, the data is automatically saved and the end result is higher than 28 degrees when controlling cooling devices to start cooling, cooling to 25 degrees to stop them.

It is necessary to control the apparatus of riscaldamento:

1: Si prega di impostare in modalità H nel codice P0.

2: Nel caso in cui si manifesti la temperature effettiva è necessario premere il tasto set, e il seguente testo digital di impostazione lampeggerà, quindi premere C/F (+) e SET (-) per impostare la temperatura di arresto del riscaldamento, dopo limpostazione si prega di attendere. 3 Secondi, confermerà automaticamente di tornare.

3: Impostazione della differenza di ritorno: in primo luogo si prega di premere il tasto SET per cinque secondi tutto il tempo, e enterà nel menu principale delle impostazioni, in secondo luogo premere STC (+) and C / F (-) per passare a P1, quando si passa P1. , Premier STC (+) e C / f (-) una volta alla volta, la cifra P1 lampeggerà, quindi premere STC (+) e C / f (-) per impostare il valore della differenza (differenza di ritorno significa che è necessario aggiungere diversi gradi per iniziare, ad esempio, se si ferma quando la TemTemTemTemTemTempo Ione dellarresto è di 25 gradi, è necessario impostare la temperatura di riscaldamento su valore 1 essere impostato a 3 grade, quindi il valore della differenza di ritorno è di 3 degrees), dopo averlo terminato, premere contemporaneamente STC (+) C/F. by conferby by conferMare.

4: Quando tutti i passaggi predenti sono stati impostati, i dati vengono salvati automaticamente, in modo da controllare lapparecchiatura di riscaldamento, avvierà il sistema di riscaldamento a meno di 22 gradi e smetterà qua ndo ladar di gsi

Product information