Feature

●Dual Output: Thermostat and Humidity Controller You can control temperature and humidity at the same time. This product has a two-stage output with temperature and humidity sensor that soothes you. This temperature and humidity controller can display the measured temperature and temperature at the same time adjust the temperature.
●Cooling mode: when the detection temperature is ≥ the starting temperature, the cooling device starts to work; when the detection temperature is ≤ stop temperature, the cooling device will stop operation. It starts with cooling or heating, humidifying or dehumidifying according to the configured parameters, which helps maintain the desired temperature and humidity at all times.
●Heating mode: when the detection temperature is ≤ the starting temperature, the heater starts to work; when the detection temperature is ≥ stop temperature, the heater will stop operation.
●Automatic detection: when the start temperature is higher than the stop temperature, switch to cooling mode C; If the start temperature is lower than the stop temperature, switch to heating mode H.
●MULTIFUNCTIONAL SETTING Support calibration, compressor delay and save reset setting values. Celsius or Fahrenheit degree display, easy to adjust. High or low temperature and humidity alarms are available. And with temperature calibration and compressor delay to protect the cooling device. It can store the original setting values in case the device is accidentally turned off.


Description

Specification:
Item Type:Temperature Humidity Controller
Material: ABS
Model: XY WTH1
Temperature measurement range: -20°C to 60°C.
Humidity range: 00% to 100% RH.
Control accuracy: 0.1℃ 0.1% RH.
Detection probe: built-in sensor.
Output Type: Relay Output
Output capacity: up to 10 A.
Temperature correction function OFE (-10.0°C to 10.0°C):
Value;
How to set the start and stop temperature:
1. In the running user interface, press and hold the TM+ button for more than 3 seconds to enter the user interface to set the start temperature. Tests can be performed by changing parameters using the TM+ TM- button. After the parameter change is complete, wait 6 seconds for the process to be automatically finished and saved.
2. In the running user interface, press and hold the TM button for more than 3 seconds to enter the setting interface for the stop temperature. Tests can be performed by changing parameters using the TM+ TM- button. After the parameter change is complete, wait 6 seconds to automatically stop and save the process.
The moisture function is as follows:
1. Automatic detection of working mode:
Automatic detection of the working mode based on the start or stop humidity.
Start humidity > stop humidity, dehumidification mode, start humidity 2. Dehumidification mode:
When the detection humidity is ≥ starting humidity, the relay is connected, the green indicator light lights up and the dehumidification device starts to work.
When the detection humidity is ≤ stop humidity, the relay turns on, the green indicator light is off, and the dehumidification device stops working.
3. Humidification mode:
If