Feature(may vary by option.)

●1. Function: If the line has overvoltage, undervoltage or overcurrent, the voltage protector can immediately interrupt the power supply to protect the electrical equipment from damage; when the mains voltage is back to normal, the protection is automatically restored.
●2. 【Use】: DIN rail installation, the protector has functions such as surge protection and undervoltage protection and is suitable for users or loads with single-phase AC voltage of 230 V, 50/60 Hz and a rated operating current of 63 A and below.
●3. 【Parameters】: optional specifications: 40A, 63A, power consumption: ≤2W, electrical and mechanical life ≥ 4000 times, low power consumption of surge protection, long mechanical life, size: approx. 81 x 36 x 60 mm / 3.2 x 1.4 x 2.4 inches.
●4. 【Application】: Surge protection intervention time: 0.1s-10s (standard 0.1s), mainly used for over-voltage, undervoltage or over-current protection of distribution lines in household boxes or to protect single-phase electrical equipment.
●5. 【Safety】: Pay attention to the maximum protection current value of the protection, the zero line N of the protection is directly connected and there is no disconnect function. If the undervoltage shutdown time is greater than 0.3 seconds, the protection will not open after a power failure.

[63A]




[40A]





Description

Voltage current protectionVoltage current protection

Specifications:

Rated voltage: 230VAC 50/60HzRated voltage: 1-63A adjustable (standard 63A)/1-40A adjustable (standard 40A). Surge protection value range: 221V-300V-OFF adjustable (standard 280V). Surge recovery voltage transmission range: 220 V-299 V (standard value 250 V). Surge protection action time: 0.1 s.10 s (standard 0.1 seconds). Undervoltage protection value range: 219 V-150 V-OFF adjustable (standard 160 V). Conveying range of the undervoltage extension: 151 V-220 V (standard value 180 V). Undervoltage protection. Action time: 0.1 s.10 s (standard 0.1 seconds). Overcurrent control range: 1 63A (-63A Standard 63A)/1-40A (standard 40A). Overcurrent action range: 0.1s -512s (standard 5.0 seconds). Delay of error recovery: 2s.512s (standard 60 seconds). Power on delay: 2s. 255s (255Standard 2 seconds)Power consumption: ≤ 2WEElectrical mechanical life: ≥ 4000 timesMounting type: top-hat rail

Power protection devicePower protection device
Voltage current protectionVoltage current protection

230VAC 63A power protection device

This is a 230 V 63 A single-phase adjustable overvoltage under-voltage current protection, the main feature is that the cable has over or under voltage, over current state, the product can immediately turn off the power supply, protect the electrical equipment from damage; if the cable is voltage voltage again is normal. the protection can be automatically and normally

Power protection devicePower protection device

Power protection devicePower protection device

Power protection devicePower protection device

Use

DIN rail installation, the protector has functions such as surge protection and undervoltage protection and is suitable for users or loads with single-phase AC voltage of 230 V, 50/60 Hz and a rated operating current of 63 A and below.

Parameters

Power consumption: ≤ 2W, electrical and mechanical life ≥ 4000 times, low power consumption of surge protector, long mechanical life, size: approx. 81 x 36 x 60 mm / 3.2 x 1.4 x 2.4 inches.

Application

Surge protection intervention time: 0.1s-10s (standard 0.1s), mainly used for overvoltage, undervoltage or overcurrent protection of distribution lines in household boxes or for protecting single-phase electrical appliances.

Protector de Corriente de VoltajeProtector de Corriente de Voltaje

Safety

Pay attention to the maximum protection current value of the protection, the zero line N of the protector is directly connected and there is no disconnect function. If the undervoltage shut-off time is greater than 0.3 seconds, the protection will not open after a power failure.

Product information