Feature

●Backward input protection: the timer module supports reverse input protection, and there is a stop button for the emergency stop function with clear interface, simple and powerful automatic saving: in the event of a power failure, all set parameters are automatically saved. With optical coupling isolation, improved anti-interference ability, circuit board. on industrial stage
●Specifications:Voltage: 6V~30V(support micro USB 5.0V)Trigger signal source: high voltage level trigger(3.0V~24V), signal ground and system ground are not connected to improve the interference immunity of the system (or you can connect them).
●6V to 30V --- The timer switch module is of the wide DC power supply. Supply voltage from 6V to 30V, support micro USB 5.0V power supply, very convenient to use sleep mode --- The timer module is in sleep mode. The display will automatically turn off if no operation is done 5 minutes after activation. You can press any button to wake it up
●Load capacity: DC 30V 5A, AC 220V 5A rest current: 20mABOperating current: 50mABOperating temperature: -40 ~ 85 Size: 6.2 × 3.8 × 1.7 cmTime range: 0.1 seconds to 999 minutes (infinitely adjustable)
●OP CL LOP --- You can set different OP, CL and LOP parameters. These parameters were independent and were saved


Description

Note: Please note that the new type and old type of this product will be sent randomly, and make sure you do not mind before ordering.

Operating mode:
P1: After triggering the signal, the switch is connected for the "OP" time and then disconnected. Within the "OP" time:
P1.1: If the signal is triggered again, it is invalid.
P1.2: When the trigger signal sounds again, restart the timing.
P1.3: When the trigger signal sounds again, the switch is not connectedP-2: After triggering the signal, the switch is disconnected for the "CL" time, then the switch is connected for the "OP" time and disconnected after the timing. P3.1: After triggering the signal, the switch is connected for the "OP" time, then the switch for the "CL" -time time separated and entered into the loop. If the signal is triggered during the loop, the switch is not connected and stops the timing. The loop times (LOP) can be set.
P3.2: After switching on, no trigger signal is required, the switch is connected for the "OP" time, then disconnected for the "CL" time and enters the loop. The loop times (LOP) can be adjusted. P-4: signal hold function. If there is a trigger signal, the time setting is reset, the switch remains connected. When the signal disappears, it will be after the "OP" time underunderunderunderIf there is a signal during the timing, the timing is reset.
OP: connection time.CL: time disconnect.LOP: loop times (1 ~ 999, "---" indicates infinite times).